P

Packing Factor — The ratio of solar collector array area to actual land area.

Pane (Window) — The area of glass that fits in the window frame.

Panel (Solar) — A term generally applied to individual solar collectors, and typically to solar photovoltaic collectors or modules.

Panel Radiator — A mainly flat surface for transmitting radiant energy.

Panemone — A drag-type wind machine that can react to wind from any direction.

Parabolic Aluminized Reflector Lamp — A type of lamp having a lens of heavy durable glass that focuses the light. They have longer lifetimes with less lumen depreciation than standard incandescent lamps.

Parabolic Dish — A solar energy conversion device that has a bowl shaped dish covered with a highly reflective surface that tracks the sun and concentrates sunlight on a fixed absorber, thereby achieving high temperatures, for process heating or to operate a heat (Stirling) engine to produce power or electricity.

Parabolic Trough — A solar energy conversion device that uses a trough covered with a highly reflective surface to focus sunlight onto a linear absorber containing a working fluid that can be used for medium temperature space or process heat or to operate a steam turbine for power or electricity generation.

Parallel — A configuration of an electrical circuit in which the voltage is the same across the terminals. The positive reference direction for each resistor current is down through the resistor with the same voltage across each resistor.

Particulates — The fine liquid or solid particles contained in combustion gases. The quantity and size of particulates emitted by cars, power and industrial plants, wood stoves, etc are regulated by the U.S. Environmental Protection Agency.

Parallel Connection — A way of joining photovoltaic cells or modules by connecting positive leads together and negative leads together; such a configuration increases the current, but not the voltage.

Passivation — A chemical reaction that eliminates the detrimental effect of electrically reactive atoms on a photovoltaic cell's surface.

Passive/Natural Cooling — To allow or augment the natural movement of cooler air from exterior, shaded areas of a building through or around a building.

Passive Solar (Building) Design — A building design that uses structural elements of a building to heat and cool a building, without the use of mechanical equipment, which requires careful consideration of the local climate and solar energy resource, building orientation, and landscape features, to name a few. The principal elements include proper building orientation, proper window sizing and placement and design of window overhangs to reduce summer heat gain and ensure winter heat gain, and proper sizing of thermal energy storage mass (for example a Trombe wall or masonry tiles). The heat is distributed primarily by natural convection and radiation, though fans can also be used to circulate room air or ensure proper ventilation.

Passive Solar Heater — A solar water or space-heating system in which solar energy is collected, and/or moved by natural convection without using pumps or fans. Passive systems are typically integral collector/storage (ICS; or batch collectors) or thermosyphon systems. The major advantage of these systems is that they do not use controls, pumps, sensors, or other mechanical parts, so little or no maintenance is required over the lifetime of the system.

Passive Solar Home — A house built using passive solar design techniques.

Payback Period — The amount of time required before the savings resulting from your system equal the system cost.

Peak Clipping/Shaving — The process of implementing measures to reduce peak power demands on a system.

Peak Demand/Load — The maximum energy demand or load in a specified time period.

Peaking Capacity — Power generation equipment or system capacity to meet peak power demands.

Peaking Hydropower — A hydropower plant that is operated at maximum allowable capacity for part of the day and is either shut down for the remainder of the time or operated at minimal capacity level.

Peak Power — Power generated that operates at a very low capacity factor; generally used to meet short-lived and variable high demand periods.

Peak Shifting — The process of moving existing loads to off-peak periods.

Peak Sun Hours — The equivalent number of hours per day when solar irradiance averages 1 kW/m2. For example, six peak sun hours means that the energy received during total daylight hours equals the energy that would have been received had the irradiance for six hours been 1 kW/m2.

Peak Watt — A unit used to rate the performance of a solar photovoltaic (PV) cells, modules, or arrays; the maximum nominal output of a PV device, in Watts (Wp) under standardized test conditions, usually 1000 Watts per square meter of sunlight with other conditions, such as temperature specified.

Peak Wind Speed — The maximum instantaneous wind speed (or velocity) that occurs within a specific period of time or interval.

Pellets — Solid fuels made from primarily wood sawdust that is compacted under high pressure to form small (about the size of rabbit feed) pellets for use in a pellet stove.

Pellet Stove — A space heating device that burns pellets; are more efficient, clean burning, and easier to operate relative to conventional cord wood burning appliances.

Pelton Turbine — A type of impulse hydropower turbine where water passes through nozzles and strikes cups arranged on the periphery of a runner, or wheel, which causes the runner to rotate, producing mechanical energy. The runner is fixed on a shaft, and the rotational motion of the turbine is transmitted by the shaft to a generator. Generally used for high head, low flow applications.

Penstock — A component of a hydropower plant; a pipe that delivers water to the turbine.

Perfluorocarbon Tracer Gas Technique (PFT) — An air infiltration measurement technique developed by the Brookhaven National Laboratory to measure changes over time (one week to five months) when determining a building's air infiltration rate. This test cannot locate exact points of infiltration, but it does reveal long-term infiltration problems.

Performance Ratings — Solar collector thermal performance ratings based on collector efficiencies, usually expressed in Btu per hour for solar collectors under standard test or operating conditions for solar radiation intensity, inlet working fluid temperatures, and ambient temperatures.

Perimeter Heating — A term applied to warm-air heating systems that deliver heated air to rooms by means of registers or baseboards located along exterior walls.

Permeance — A unit of measurement for the ability of a material to retard the diffusion of water vapor at 73.4 F (23 C). A perm, short for permeance, is the number of grains of water vapor that pass through a square foot of material per hour at a differential vapor pressure equal to one inch of mercury.

Phantom Load — Any appliance that consumes power even when it is turned off. Examples of phantom loads include appliances with electronic clocks or timers, appliances with remote controls, and appliances with wall cubes (a small box that plugs into an AC outlet to power appliances).

Phase — Alternating current is carried by conductors and a ground to residential, commercial, or industrial consumers. The waveform of the phase power appears as a single continuous sine wave at the system frequency whose amplitude is the rated voltage of the power.

Phase Change — The process of changing from one physical state (solid, liquid, or gas) to another, with a necessary or coincidental input or release of energy.

Phase-Change Material — A material that can be used to store thermal energy as latent heat. Various types of materials have been and are being investigated such as inorganic salts, eutectic compounds, and paraffins, for a variety of applications, including solar energy storage (solar energy heats and melts the material during the day and at night it releases the stored heat and reverts to a solid state).

Photobiological Hydrogen Production — A hydrogen production process that process uses algae. Under certain conditions, the pigments in certain types of algae absorb solar energy. An enzyme in the cell acts as a catalyst to split water molecules. Some of the bacteria produces hydrogen after they grow on a substrate.

Photocurrent — An electric current induced by radiant energy.

Photoelectric Cell — A device for measuring light intensity that works by converting light falling on, or reach it, to electricity, and then measuring the current; used in photometers.

Photoelectrochemical Cell — A type of photovoltaic device in which the electricity induced in the cell is used immediately within the cell to produce a chemical, such as hydrogen, which can then be withdrawn for use.

Photoelectrolysis Hydrogen Production — The production of hydrogen using a photoelectrochemical cell.

Photogalvanic Processes — The production of electrical current from light.

Photon — A particle of light that acts as an individual unit of energy.

Photovoltaic (Conversion) Efficiency — The ratio of the electric power produced by a photovoltaic device to the power of the sunlight incident on the device.

Photovoltaic (PV; Solar) Array — A group of solar photovoltaic modules connected together.

Photovoltaic (Solar) Cell — Treated semiconductor material that converts solar irradiance to electricity.

Photovoltaic Device — A solid-state electrical device that converts light directly into direct current electricity of voltage-current characteristics that are a function of the characteristics of the light source and the materials in and design of the device. Solar photovoltaic devices are made of various semi-conductor materials including silicon, cadmium sulfide, cadmium telluride, and gallium arsenide, and in single crystalline, multi-crystalline, or amorphous forms.

Photovoltaic (Solar) Module or Panel — A solar photovoltaic product that generally consists of groups of PV cells electrically connected together to produce a specified power output under standard test conditions, mounted on a substrate, sealed with an encapsulant, and covered with a protective glazing. Maybe further mounted on an aluminum frame. A junction box, on the back or underside of the module is used to allow for connecting the module circuit conductors to external conductors.

Photovoltaic Peak Watt — see Peak Watt.

Photovoltaic (Solar) System — A complete PV power system composed of the module (or array), and balance-of-system (BOS) components including the array supports, electrical conductors/wiring, fuses, safety disconnects, and grounds, charge controllers, inverters, battery storage, etc.

Photovoltaic-Thermal (PV/T) Systems — A solar energy system that produces electricity with a PV module, and collects thermal energy from the module for heating. There are no commercially available systems available (as of 11/97).

Physical Vapor Deposition — A method of depositing thin semiconductor photovoltaic) films. With this method, physical processes, such as thermal evaporation or bombardment of ions, are used to deposit elemental semiconductor material on a substrate.

Pitch Control — A method of controlling a wind turbine's speed by varying the orientation, or pitch, of the blades, and thereby altering its aerodynamics and efficiency.

P-I-N — A semiconductor (photovoltaic) device structure that layers an intrinsic semiconductor between a p-type semiconductor and an n-type semiconductor; this structure is most often used with amorphous silicon PV devices.

P/N — A semiconductor (photovoltaic) device structure in which the junction is formed between a p-type layer and an n-type layer.

Plenum — The space between a hanging ceiling and the floor above or roof; usually contains HVAC ducts, electrical wiring, fire suppression system piping, etc.

Plug Flow Digester — A type of anaerobic digester that has a horizontal tank in which a constant volume of material is added and forces material in the tank to move through the tank and be digested.

Point-Contact Cell — A high efficiency silicon photovoltaic concentrator cell that employs light trapping techniques and point-diffused contacts on the rear surface for current collection.

Polycrystalline — A semiconductor (photovoltaic) material composed of variously oriented, small, individual crystals.

Polyethylene — A registered trademark for plastic sheeting material that can be used as a vapor retarder. This plastic is used to make grocery bags. It is a long chain of carbon atoms with 2 hydrogen atoms attached to each carbon atom.

Polystyrene (see Foam Insulation)

Porous Media — A solid that contains pores; normally, it refers to interconnected pores that can transmit the flow of fluids. (The term refers to the aquifer geology when discussing sites for CAES.)

Portfolio Standard — The requirement that an electric power provider generate or purchase a specified percentage of the power it supplies/sells from renewable energy resources, and thereby guarantee a market for electricity generated from renewable energy resources.

Potable Water — Water that is suitable for drinking, as defined by local health officials.

Potential Energy — Energy available due to position.

Pound of Steam — One pound of water in vapor phase; is NOT steam pressure, which is expressed as pounds per square inch (psi).

Pound Per Square Inch Absolute (psia) — A unit of pressure [hydraulic (liquid) or pneumatic (gas)] that does not include atmospheric pressure.

Power — Energy that is capable or available for doing work; the time rate at which work is performed, measured in horsepower, Watts, or Btu per hour. Electric power is the product of electric current and electromotive force.

Power Coefficient — The ratio of power produced by a wind energy conversion device to the power in a reference area of the free windstream.

Power Conditioning — The process of modifying the characteristics of electrical power (for e.g., inverting dc to ac).

Power (Output) Curve — A plot of a wind energy conversion device's power output versus wind speed.

Power Density — The amount of power per unit area of a free windstream.

Power Factor (PF) — The ratio of actual power being used in a circuit, expressed in watts or kilowatts, to the power that is apparently being drawn from a power source, expressed in volt-amperes or kilovolt-amperes.

Power Generation Mix — The proportion of electricity distributed by a power provider that is generated from available sources such as coal, natural gas, petroleum, nuclear, hydropower, wind, or geothermal.

Power Provider — A company or other organizational unit that sells and distributes electrical power (e.g., private or public electrical utility), either to other distribution and wholesale businesses or to end-users. Sometimes power providers also generate the power they sell.

Power (Solar) Tower — A term used to describe solar thermal, central receiver, power systems, where an array of reflectors focus sunlight onto a central receiver and absorber mounted on a tower.

Power Transmission Line — An electrical conductor/cable that carries electricity from a generator to other locations for distribution.

Preheater (Solar) — A solar heating system that preheats water or air that is then heated more by another heating appliance.

Present Value — The amount of money required to secure a specified cash flow at a future date at a specified return.

Pressure Drop — The loss in static pressure of a fluid (liquid or gas) in a system due to friction from obstructions in pipes, from valves, fittings, regulators, burners, etc, or by a breech or rupture of the system.

Pressurization Testing — A technique used by energy auditors, using a blower door, to locate areas of air infiltration by exaggerating the defects in the building shell. This test only measures air infiltration at the time of the test. It does not take into account changes in atmospheric pressure, weather, wind velocity, or any activities the occupants conduct that may affect air infiltration rates over a period of time.

Primary Air — The air that is supplied to the combustion chamber of a furnace.

Prime Mover — Any machine capable of producing power to do work.

Process Heat — Thermal energy that is used in agricultural and industrial operations.

Products of Combustion — The elements and compounds that result from the combustion of a fuel.

Producer Gas — Low or medium Btu content gas, composed mainly of carbon monoxide, nitrogen(2), and hydrogen(2) made by the gasification of wood or coal.

Programmable Thermostat — A type of thermostat that allows the user to program into the devices' memory a pre-set schedule of times (when certain temperatures occur) to turn on HVAC equipment.

Projected Area — The net south-facing glazing area projected on a vertical plane. Also, the solid area covered at any instant by a wind turbine's blades from the perspective of the direction of the windstream (as opposed to the swept area).

Propane — A hydrocarbon gas, C3H8, occurring in crude oil, natural gas, and refinery cracking gas. It is used as a fuel, a solvent, and a refrigerant. Propane liquefies under pressure and is the major component of liquefied petroleum gas (LPG).

Propeller (Hydro) Turbine — A turbine that has a runner with attached blades similar to a propeller used to drive a ship. As water passes over the curved propeller blades, it causes rotation of the shaft.

Proximate Analysis — A commonly used analysis for reporting fuel properties; may be on a dry (moisture free) basis, as "fired", or on an ash and moisture free basis. Fractions usually reported include: volatile matter, fixed carbon, moisture, ash, and heating value (higher heating value).

Psi — Pounds of pressure per square inch.

Psia — Pounds/force per square inch absolute.

Psig — Pounds/force per square inch gauge.

Psychrometer — An instrument for measuring relative humidity by means of wet and dry-bulb temperatures.

Psychrometrics — The analysis of atmospheric conditions, particularly moisture in the air.

P-Type Semiconductor — A semiconductor in which holes carry the current; produced by doping an intrinsic semiconductor with an electron acceptor impurity (e.g., boron in silicon).

Public Utility Holding Company Act (PUHCA) of 1935 — A law to protect consumers and investors. It placed geographic restrictions on mergers and limitations on diversification into non-utility lines of business and takeovers of electric and gas utilities, and also established regulated monopoly markets or service territories for utilities.

Public Utilities Regulatory Policy Act (PURPA) of 1978 — A law that requires electric utilities to purchase electricity produced from qualifying power producers that use renewable energy resources or are cogenerators. Power providers are required to purchase power at a rate equal to the avoided cost of generating the power themselves. (See Avoided Costs and Qualifying Facility)

Public Utility or Services Commissions (PUC or PSC) — These are state government agencies responsible for the regulation of public utilities within a state or region. A state legislature oversees the PUC by reviewing changes to power generator laws, rules and regulations and approving the PUC's budget. The commission usually has five Commissioners appointed by the Governor or legislature. PUCs typically regulate: electric, natural gas, water, sewer, telephone services, trucks, buses, and taxicabs within the commission's operating region. The PUC tries to balance the interests of consumers, environmentalists, utilities, and stockholders. The PUC makes sure a region's citizens are supplied with adequate, safe power provider service at reasonable rates.

Pulse-Width-Modulated (PWM) Wave Inverter — A type of power inverter that produce a high quality (nearly sinusoidal) voltage, at minimum current harmonics.

Pumped Storage Facility — A type of power generating facility that pumps water to a storage reservoir during off-peak periods, and uses the stored water (by allowing it to fall through a hydro turbine) to generate power during peak periods. The pumping energy is typically supplied by lower cost base power capacity, and the peaking power capacity is of greater value, even though there is a net loss of power in the process.

Pyranometer — A device used to measure total incident solar radiation (direct beam, diffuse, and reflected radiation) per unit time per unit area.

Pyrheliometer — A device that measures the intensity of direct beam solar radiation.

Pyrolysis — The transformation on a compound or material into one or more substances by heat alone (without oxidation). Often called destructive distillation. Pyrolysis of biomass is the thermal degradation of the material in the absence of reacting gases, and occurs prior to or simultaneously with gasification reactions in a gasifier. Pyrolysis products consist of gases, liquids, and char generally. The liquid fraction of pyrolisized biomass consists of an insoluble viscous tar, and pyroligneous acids (acetic acid, methanol, acetone, esters, aldehydes, and furfural). The distribution of pyrolysis products varies depending on the feedstock composition, heating rate, temperature, and pressure.

Q

Quad — One quadrillion Btu. (1,000,000,000,000,000 Btu)

Qualifying Facility — A category of electric power producer established under the Public Utility Regulatory Policy Act (PURPA) of 1978, that includes small-power producers (SPP) who use renewable sources of energy such as biomass, geothermal, hydroelectricity, solar (thermal and photovoltaic), and wind, or cogenerators who produce both heat and electricity using any type of fuel. PURPA requires utilities to purchase electricity from these power producers at a rate approved by a state utility regulatory agency under Federal guidelines. PURPA also requires power providers to sell electricity to these producers. Some states have developed their own programs for SPPs and utilities.

R

Radiant Barrier — A thin, reflective foil sheet that exhibits low radiant energy transmission and under certain conditions can block radiant heat transfer; installed in attics to reduce heat flow through a roof assembly into the living space.

Radiant Ceiling Panels — Ceiling panels that contain electric resistance heating elements embedded within them to provide radiant heat to a room.

Radiant Energy — Energy that transmits away from its source in all directions.

Radiant Floor — A type of radiant heating system where the building floor contains channels or tubes through which hot fluids such as air or water are circulated. The whole floor is evenly heated. Thus, the room heats from the bottom up. Radiant floor heating eliminates the draft and dust problems associated with forced air heating systems.

Radiant Heating System — A heating system where heat is supplied (radiated) into a room by means of heated surfaces, such as electric resistance elements, hot water (hydronic) radiators, etc.

Radiation — The transfer of heat through matter or space by means of electromagnetic waves.

Radiative Cooling — The process of cooling by which a heat absorbing media absorbs heat from one source and radiates the heat away.

Radiator — A room heat delivery (or exchanger) component of a hydronic (hot water or steam) heating system; hot water or steam is delivered to it by natural convection or by a pump from a boiler.

Radiator Vent — A device that releases pressure within a radiator when the pressure inside exceeds the operating limits of the vent.

Radioactive Waste — Materials left over from making nuclear energy. Radioactive waste can living organisms if it is not stored safely.

Radon — A naturally occurring radioactive gas found in the U.S. in nearly all types of soil, rock, and water. It can migrate into most buildings. Studies have linked high concentrations of radon to lung cancer.

Rafter — A construction element used for ceiling support.

Rammed Earth — A construction material made by compressing earth in a form; used traditionally in many areas of the world and widely throughout North Africa and the Middle East.

Rankine Cycle — The thermodynamic cycle that is an ideal standard for comparing performance of heat-engines, steam power plants, steam turbines, and heat pump systems that use a condensable vapor as the working fluid; efficiency is measured as work done divided by sensible heat supplied.

Rated Life — The length of time that a product or appliance is expected to meet a certain level of performance under nominal operating conditions; in a luminaire, the period after which the lumen depreciation and lamp failure is at 70% of its initial value.

Rated Power — The power output of a device under specific or nominal operating conditions.

Rate Schedule — A mechanism used by electric utilities to determine prices for electricity; typically defines rates according to amounts of power demanded/consumed during specific time periods.

Rayleigh Frequency Distribution — A mathematical representation of the frequency or ratio that specific wind speeds occur within a specified time interval.

Reactive Power — The electrical power that oscillates between the magnetic field of an inductor and the electrical field of a capacitor. Reactive power is never converted to non-electrical power. Calculated as the square root of the difference between the square of the kilovolt-amperes and the square of the kilowatts. Expressed as reactive volt-amperes.

Real Price — The unit price of a good or service estimated from some base year in order to provide a consistent means of comparison.

Recirculation Systems — A type of solar heating system that circulate warm water from storage through the collectors and exposed piping whenever freezing conditions occur; obviously a not very efficient system when operating in this mode.

Receiver — The component of a central receiver solar thermal system where reflected solar energy is absorbed and converted to thermal energy.

Recirculated Air — Air that is returned from a heated or cooled space, reconditioned and/or cleaned, and returned to the space.

Rectifier — An electrical device for converting alternating current to direct current. The chamber in a cooling device where water is separated from the working fluid (for example ammonia).

Recuperator — A heat exchanger in which heat is recovered from the products of combustion.

Recurrent Costs — Costs that are repetitive and occur when an organization produces similar goods or services on a continuing basis.

Recycling — The process of converting materials that are no longer useful as designed or intended into a new product.

Reflectance — The amount (percent) of light that is reflected by a surface relative to the amount that strikes it.

Reflective Coatings — Materials with various qualities that are applied to glass windows before installation. These coatings reduce radiant heat transfer through the window and also reflects outside heat and a portion of the incoming solar energy, thus reducing heat gain. The most common type has a sputtered coating on the inside of a window unit. The other type is a durable "hard-coat" glass with a coating, baked into the glass surface.

Reflective Window Films — A material applied to window panes that controls heat gain and loss, reduces glare, minimizes fabric fading, and provides privacy. These films are retrofitted on existing windows.

Reflective Glass — A window glass that has been coated with a reflective film and is useful in controlling solar heat gain during the summer.

Reflective Insulation (see also radiant barrier) — An aluminum foil fabricated insulator with backings applied to provide a series of closed air spaces with highly reflective surfaces.

Reflector Lamps — A type of incandescent lamp with an interior coating of aluminum that reflects light to the front of the bulb. They are designed to spread light over specific areas.

Refraction — The change in direction of a ray of light when it passes through one media to another with differing optical densities.

Refrigerant — The compound (working fluid) used in air conditioners, heat pumps, and refrigerators to transfer heat into or out of an interior space. This fluid boils at a very low temperature enabling it to evaporate and absorb heat.

Refrigeration — The process of the absorption of heat from one location and its transfer to another for rejection or recuperation.

Refrigeration Capacity — A measure of the effective cooling capacity of a refrigerator, expressed in Btu per hour or in tons, where one (1) ton of capacity is equal to the heat required to melt 2,000 pounds of ice in 24 hours or 12,000 Btu per hour.

Refrigeration Cycle — The complete cycle of stages (evaporation and condensation) of refrigeration or of the refrigerant.

Refuse-Derived Fuel (RDF) — A solid fuel produced by shredding municipal solid waste (MSW). Noncombustible materials such as glass and metals are generally removed prior to making RDF. The residual material is sold as-is or compressed into pellets, bricks, or logs. RDF processing facilities are typically located near a source of MSW, while the RDF combustion facility can be located elsewhere. Existing RDF facilities process between 100 and 3,000 tons per day.

Regenerative Cooling — A type of cooling system that uses a charging and discharging cycle with a thermal or latent heat storage subsystem.

Regenerative Heating — The process of using heat that is rejected in one part of a cycle for another function or in another part of the cycle.

Relamping — The replacement of a non-functional or ineffective lamp with a new, more efficient lamp.

Relative Humidity — A measure of the percent of moisture actually in the air compared with what would be in it if it were fully saturated at that temperature. When the air is fully saturated, its relative humidity is 100 percent.

Reliability — This is the concept of how long a device or process can operate properly without needing maintenance or replacement.

Renewable Energy — Energy derived from resources that are regenerative or for all practical purposes can not be depleted. Types of renewable energy resources include moving water (hydro, tidal and wave power), thermal gradients in ocean water, biomass, geothermal energy, solar energy, and wind energy. Municipal solid waste (MSW) is also considered to be a renewable energy resource.

Resistance — The inherent characteristic of a material to inhibit the transfer of energy. In electrical conductors, electrical resistance results in the generation of heat. Electrical resistance is measured in Ohms. The heat transfer resistance properties of insulation products are quantified as the R-value.

Resistance Heating — A type of heating system that provides heat from the resistance of an electrical current flowing through a conductor.

Resistive Voltage Drop — The voltage developed across a cell by the current flow through the resistance of the cell.

Resistor — An electrical device that resists electric current flow.

Resource Recovery — The process of converting municipal solid waste to energy and/or recovering materials for recycling.

Restructuring — The process of changing the structure of the electric power industry from one of guaranteed monopoly over service territories, as established by the Public Utility Holding Company Act of 1935, to one of open competition between power suppliers for customers in any area.

Retrofit — The process of modifying a building's structure.

Return Air — Air that is returned to a heating or cooling appliance from a heated or cooled space.

Return Duct — The central heating or cooling system contains a fan that gets its air supply through these ducts, which ideally should be installed in every room of the house. The air from a room will move towards the lower pressure of the return duct.

Retail Wheeling — A term for the process of transmitting electricity over transmission lines not owned by the supplier of the electricity to a retail customer of the supplier. With retail wheeling, an electricity consumer can secure their own supply of electricity from a broker or directly from the generating source. The power is then wheeled at a fixed rate, or at a regulated "non-discriminatory" rate set by a utility commission.

Reverse Thermosiphoning — When heat seeks to flow from a warm area (e.g., heated space) to a cooler area, such as a solar air collector at night without a reverse flow damper.

Reversing Valve — A component of a heat pump that reverses the refrigerant's direction of flow, allowing the heat pump to switch from cooling to heating or heating to cooling.

R-Factor — See R-Value.

Ribbon (Photovoltaic) Cells — A type of solar photovoltaic device made in a continuous process of pulling material from a molten bath of photovoltaic material, such as silicon, to form a thin sheet of material.

Rigid Insulation Board — An insulation product made of a fibrous material or plastic foams, pressed or extruded into board-like forms. It provides thermal and acoustical insulation strength with low weight, and coverage with few heat loss paths.

Rock Bin — A container that holds rock used as the thermal mass to store solar energy in a solar heating system.

Rock Wool — A type of insulation made from virgin basalt, an igneous rock, and spun into loose fill or a batt. It is fire resistant and helps with soundproofing.

Roof — A building element that provides protection against the sun, wind, and precipitation.

Roof Pond — A solar energy collection device consisting of containers of water located on a roof that absorb solar energy during the day so that the heat can be used at night or that cools a building by evaporation at night.

Roof Ventilator — A stationary or rotating vent used to ventilate attics or cathedral ceilings; usually made of galvanized steel, or polypropylene.

Rotor — An electric generator consists of an armature and a field structure. The armature carries the wire loop, coil, or other windings in which the voltage is induced, whereas the field structure produces the magnetic field. In small generators, the armature is usually the rotating component (rotor) surrounded by the stationary field structure (stator). In large generators in commercial electric power plants the situation is reversed. In a wind energy conversion device, the blades and rotating components.

Run-of-River Hydropower — A type of hydroelectric facility that uses the river flow with very little alteration and little or no impoundment of the water.

Rural Electrification Administration (REA) — An agency of the U.S. Dept. of Agriculture that makes loans to states and territories in the U.S. for rural electrification and the furnishing of electric energy to persons in rural areas who do not receive central station service. It also furnishes and improves electric and telephone service in rural areas, assists electric borrowers to implement energy conservation programs and on-grid and off-grid renewable energy systems, and studies the condition and progress of rural electrification.

R-Value — A measure of the capacity of a material to resist heat transfer. The R-Value is the reciprocal of the conductivity of a material (U-Value). The larger the R-Value of a material, the greater its insulating properties..Zoning

.